Contrast-enhanced digital mammography and other techniques based on image subtraction

作者: María-Ester Brandan

DOI: 10.1063/1.4954122

关键词:

摘要: This article reviews research done by the author and collaborators in general area of subtraction techniques applied to radiological images, particular contrast-enhanced digital mammography (CEDM). Main achievements have been development phantom validation a formalism subtract images using dual-energy or temporal modalities, proposal hybrid modality called temporal, matrix-based compensation for energy dependence anatomical background subtraction. has validated with non-homogenous measurements clinical iodine-based contrast medium. Results from study led group correlation between CEDM image parameters angiogenic biomarkers murine breast cancer model. Clinical subtracted subjected textural analysis.

参考文章(17)
I. Rosado-Méndez, B. A. Palma, M. E. Brandan, Analytical optimization of digital subtraction mammography with contrast medium using a commercial unit. Medical Physics. ,vol. 35, pp. 5544- 5557 ,(2008) , 10.1118/1.3003063
M-E Brandan, V Ramírez-R, Evaluation of dual-energy subtraction of digital mammography images under conditions found in a commercial unit. Physics in Medicine and Biology. ,vol. 51, pp. 2307- 2320 ,(2006) , 10.1088/0031-9155/51/9/014
Clarisse Dromain, Fabienne Thibault, Serge Muller, Françoise Rimareix, Suzette Delaloge, Anne Tardivon, Corinne Balleyguier, Dual-energy contrast-enhanced digital mammography: initial clinical results European Radiology. ,vol. 21, pp. 565- 574 ,(2011) , 10.1007/S00330-010-1944-Y
Heang-Ping Chan, Datong Wei, M A Helvie, B Sahiner, D D Adler, M M Goodsitt, N Petrick, Computer-aided classification of mammographic masses and normal tissue: linear discriminant analysis in texture feature space Physics in Medicine and Biology. ,vol. 40, pp. 857- 876 ,(1995) , 10.1088/0031-9155/40/5/010
Felix Diekmann, Martin Freyer, Susanne Diekmann, Eva M. Fallenberg, Thomas Fischer, Ulrich Bick, Alexander Pöllinger, Evaluation of contrast-enhanced digital mammography European Journal of Radiology. ,vol. 78, pp. 112- 121 ,(2011) , 10.1016/J.EJRAD.2009.10.002
Michael R. Lemacks, S. Cheenu Kappadath, Chris C. Shaw, Xinming Liu, Gary J. Whitman, A dual‐energy subtraction technique for microcalcification imaging in digital mammography—A signal‐to‐noise analysis Medical Physics. ,vol. 29, pp. 1739- 1751 ,(2002) , 10.1118/1.1494832
B. A. Palma, I. Rosado-Méndez, Y. Villaseñor, M. E. Brandan, Phantom study to evaluate contrast-medium-enhanced digital subtraction mammography with a full-field indirect-detection system. Medical Physics. ,vol. 37, pp. 577- 589 ,(2010) , 10.1118/1.3276733
Douglas Hanahan, Robert A. Weinberg, Hallmarks of cancer: the next generation. Cell. ,vol. 144, pp. 646- 674 ,(2011) , 10.1016/J.CELL.2011.02.013
Juan-Pablo Cruz-Bastida, Iván Rosado-Méndez, Héctor Pérez-Ponce, Yolanda Villaseñor, Héctor A. Galván, Flavio E. Trujillo-Zamudio, Luis Benítez-Bribiesca, María-Ester Brandan, Contrast Optimization in Clinical Contrast-Enhanced Digital Mammography Images Breast Imaging. pp. 17- 23 ,(2012) , 10.1007/978-3-642-31271-7_3