作者: Tamara Kerber Tedesco , Eugenio Jose Garcia , Fabio Zovico Maxnuck Soares , Rachel de Oliveira Rocha , Rosa Helena Miranda Grande
DOI: 10.1590/0103-6440201302298
关键词:
摘要: This in vitro study evaluated the influence of two devices for application shear load microshear tests on bond strength and fracture pattern primary enamel dentin. Eighty molars were selected flat (40 teeth sectioned mesio-distally) dentin transversally) surfaces obtained. Both polished to standardize smear layer. Two-step etch-and-rinse adhesive systems (Adper Single Bond XP Bond) used. Polyethylene tubes was placed over bonded filled with composite resin. The testing performed after storage water (24 h/37 °C) using loads: a notched rod (Bisco Shear Tester) or knife edge (Kratos Industrial Equipment). Failure modes stereomicroscope. data subjected ANOVA chi-square test compare failure mode distributions (α=0.05). No significant differences observed between groups patterns (p>0.05). predominant adhesive/mixed. In conclusion, loads did not values, regardless system substrate.