Reproducibility of electromyographic and mechanical parameters of the triceps surae during submaximal and maximal plantar flexions.

作者: Norman Stutzig , Tobias Siebert

DOI: 10.1002/MUS.24767

关键词:

摘要: Introduction Neuromuscular parameters must be reproducible to examine neuromuscular adaptations in interventional and clinical studies. The reproducibility of for the soleus (SOL), lateral gastrocnemius (LG), medial (MG) was assessed over a period 2 weeks. Methods Thirteen subjects (27.4 years, 69.5 kg) were tested numerous electromyographic (e.g., voluntary electrical evoked EMG) mechanical activation level) 3 test sessions. Results majority data (28 34) revealed moderate substantial reproducibility. Hmax20% /Mmax20% Vsup /Msup less LG than MG SOL. Muscle activity M-waves did not differ between muscles. ICC >0.79. Conclusions H-reflex during contraction should considered with caution. Mechanical on muscle level are reproducible. is sufficient

参考文章(41)
Nicola A Maffiuletti, Marc Jubeau, Raphael Zory, Delphine Boerio, Central and peripheral fatigue after electrostimulation-induced resistance exercise Medicine and Science in Sports and Exercise. ,vol. 37, pp. 973- 978 ,(2005)
Norman Stutzig, Tobias Siebert, Muscle force compensation among synergistic muscles after fatigue of a single muscle. Human Movement Science. ,vol. 42, pp. 273- 287 ,(2015) , 10.1016/J.HUMOV.2015.06.001
Roy Müller, Tobias Siebert, Reinhard Blickhan, Muscle preactivation control: simulation of ankle joint adjustments at touchdown during running on uneven ground. Journal of Applied Biomechanics. ,vol. 28, pp. 718- 725 ,(2012) , 10.1123/JAB.28.6.718
Norman Stutzig, Tobias Siebert, Influence of joint position on synergistic muscle activity after fatigue of a single muscle head Muscle & Nerve. ,vol. 51, pp. 259- 267 ,(2015) , 10.1002/MUS.24305
RIANN M. PALMIERI, MARK A. HOFFMAN, CHRISTOPHER D. INGERSOLL, Intersession reliability for H-reflex measurements arising from the soleus, peroneal, and tibialis anterior musculature. International Journal of Neuroscience. ,vol. 112, pp. 841- 850 ,(2002) , 10.1080/00207450290025851
Nicolas Place, Nicola A. Maffiuletti, Alain Martin, Romuald Lepers, Assessment of the reliability of central and peripheral fatigue after sustained maximal voluntary contraction of the quadriceps muscle. Muscle & Nerve. ,vol. 35, pp. 486- 495 ,(2007) , 10.1002/MUS.20714
A. Christie, S. Lester, D. LaPierre, D.A. Gabriel, Reliability of a new measure of H-reflex excitability Clinical Neurophysiology. ,vol. 115, pp. 116- 123 ,(2004) , 10.1016/S1388-2457(03)00306-7
K. J. TUCKER, K. S. TüRKER, Muscle spindle feedback differs between the soleus and gastrocnemius in humans. Somatosensory and Motor Research. ,vol. 21, pp. 189- 197 ,(2004) , 10.1080/08990220400012489
NICOLA A. MAFFIULETTI, SERGIO DUGNANI, MATTEO FOLZ, ERMANO DI PIERNO, FRANCO MAURO, Effect of combined electrostimulation and plyometric training on vertical jump height. Medicine and Science in Sports and Exercise. ,vol. 34, pp. 1638- 1644 ,(2002) , 10.1097/00005768-200210000-00016
Kylie J. Tucker, Meltem Tuncer, Kemal S. Türker, A review of the H-reflex and M-wave in the human triceps surae. Human Movement Science. ,vol. 24, pp. 667- 688 ,(2005) , 10.1016/J.HUMOV.2005.09.010