Mapping of proton relaxation near superparamagnetic iron oxide particle-loaded polymer threads for magnetic susceptibility difference quantification.

作者: Hank C.W. Donker , Nils A. Krämer , Jens Otto , Uwe Klinge , Ioana Slabu

DOI: 10.1097/RLI.0B013E3182484FDF

关键词: Nuclear magnetic resonancePolymerThread (computing)Magnetic resonance imagingMaterials scienceMagnetic susceptibilitySuperparamagnetic iron oxide

摘要: ObjectivesConventional radiological methods, including magnetic resonance imaging (MRI), fail to visualize polymeric surgical mesh implants because of small thread dimensions and material characteristics. For MRI delineation such meshes, superparamagnetic iron oxide particles (SPIOs) are integrat

参考文章(35)
Jian Guo, Xiqun Jiang, Yong Hu, Changzheng Yang, Preparation of Gd3+-containing polymer complex as a novel magnetic resonance signal-enhancing coating material. Journal of Materials Science: Materials in Medicine. ,vol. 14, pp. 283- 286 ,(2003) , 10.1023/A:1022849227694
A Sharma, V Soni, M Baijal, PK Chowbey, T Mittal, V Kumar, R Khullar, Diagnosis and management of Spigelian hernia: A review of literature and our experience Journal of Minimal Access Surgery. ,vol. 4, pp. 95- ,(2008) , 10.4103/0972-9941.45204
K.M. Lüdeke, P. Röschmann, R. Tischler, Susceptibility artefacts in NMR imaging. Magnetic Resonance Imaging. ,vol. 3, pp. 329- 343 ,(1985) , 10.1016/0730-725X(85)90397-2
J.W.M. Bulte, R.A. Brooks, B.M. Moskowitz, L.H. Bryant,, J.A. Frank, Relaxometry and magnetometry of the MR contrast agent MION-46L. Magnetic Resonance in Medicine. ,vol. 42, pp. 379- 384 ,(1999) , 10.1002/(SICI)1522-2594(199908)42:2<379::AID-MRM20>3.0.CO;2-L
Ján Weis, L'uboš Budinský, Simulation of the influence of magnetic field inhomogeneity and distortion correction in MR imaging. Magnetic Resonance Imaging. ,vol. 8, pp. 483- 489 ,(1990) , 10.1016/0730-725X(90)90056-8
U. Klinge, B. Klosterhalfen, V. Birkenhauer, K. Junge, J. Conze, V. Schumpelick, Impact of Polymer Pore Size on the Interface Scar Formation in a Rat Model Journal of Surgical Research. ,vol. 103, pp. 208- 214 ,(2002) , 10.1006/JSRE.2002.6358
Stefan Widmaier, Wulf-Ingo Jung, Karin Pfeffer, Markus Pfeffer, Otto Lutz, MRI and determination of T1 and T2 of solid polymers using a 1.5 T whole-body imager. Magnetic Resonance Imaging. ,vol. 11, pp. 733- 737 ,(1993) , 10.1016/0730-725X(93)90016-7
Xiaoqing Qiu, Liping Li, Xianzhi Fu, Guangshe Li, Synthesis, physicochemical characterization and MR relaxometry of aqueous ferrofluids. Journal of Nanoscience and Nanotechnology. ,vol. 8, pp. 2399- 2409 ,(2008) , 10.1166/JNN.2008.312