Ultrasound Biomicroscopic Findings in Humans With Shallow Anterior Chamber and Increased Intraocular Pressure After the Prone Provocation Test

作者: TAKEHISA KONDO , DAISUKE MIYAZAWA , KUNIKO UNIGAME , YASUO KURIMOTO

DOI: 10.1016/S0002-9394(14)70901-8

关键词: Open angle glaucomaEye diseaseProvocation testShallow anterior chamberOphthalmologyGlaucomaUltrasound biomicroscopyIntraocular pressureUltrasoundMedicine

摘要: Purpose To investigate ultrasound biomicroscopic findings in human eyes with shallow anterior chamber and risk of angle-closure glaucoma after the prone provocation test. Methods A total 32 consecutive patients (64 eyes) bilateral who were at for primary underwent test a lit room. Before immediately measurement intraocular pressure this test, high-frequency biomicroscopy was performed horizontal vertical directions, angle views recorded 3-, 6-, 9-, 12-o'clock positions. Results Ten six exhibited an increase 8 mm Hg or more, positive response, remainder showing negative response to In profile iris showed markedly convex shape large space behind posterior iris. However, each eye remained open, even during high level caused by provocation. Conclusions The present results suggest that no closure occurs initial Such associated because relative pupillary block. time lag observed between block occurrence closure.

参考文章(16)
Duke-Elder, Stewart, Sir, Diseases of the lens and vitreous : glaucoma and hypotony Kimpton. ,(1969)
FS Foster, Charles J. Pavlin, Ultrasound Biomicroscopy of the Eye ,(1994)
R Mapstone, One gonioscopic fallacy. British Journal of Ophthalmology. ,vol. 63, pp. 221- 224 ,(1979) , 10.1136/BJO.63.4.221
P. T. Hung, L. H. Chou, Provocation and Mechanism of Angle-Closure Glaucoma After Iridectomy Archives of Ophthalmology. ,vol. 97, pp. 1862- 1864 ,(1979) , 10.1001/ARCHOPHT.1979.01020020310003
Charles J. Pavlin, Robert Ritch, F. Stuart Foster, Ultrasound Biomicroscopy in Plateau Iris Syndrome American Journal of Ophthalmology. ,vol. 113, pp. 390- 395 ,(1992) , 10.1016/S0002-9394(14)76160-4
L. S. Harris, M. A. Galin, Prone Provocative Testing for Narrow Angle Glaucoma Archives of Ophthalmology. ,vol. 87, pp. 493- 496 ,(1972) , 10.1001/ARCHOPHT.1972.01000020495001
R Mapstone, Mechanics of pupil block. British Journal of Ophthalmology. ,vol. 52, pp. 19- 25 ,(1968) , 10.1136/BJO.52.1.19
I M Aslanides, P E Libre, R H Silverman, D Z Reinstein, D R Lazzaro, M J Rondeau, G K Harmon, D J Coleman, High frequency ultrasound imaging in pupillary block glaucoma British Journal of Ophthalmology. ,vol. 79, pp. 972- 976 ,(1995) , 10.1136/BJO.79.11.972
Robert Ritch, Plateau Iris Is Caused by Abnormally Positioned Ciliary Processes Journal of Glaucoma. ,vol. 1, pp. 23- 26 ,(1992) , 10.1097/00061198-199204000-00006
T. Kondo, M. Miura, A method of measuring pupil-blocking force in the human eye. Graefes Archive for Clinical and Experimental Ophthalmology. ,vol. 225, pp. 361- 364 ,(1987) , 10.1007/BF02153406