Amperometric creatinine biosensor for hemodialysis patients.

作者: Bernd Tombach , Joachim Schneider , Fritz Matzkies , Roland M Schaefer , Gabriele C Chemnitius

DOI: 10.1016/S0009-8981(01)00610-6

关键词: AmperometryBiochemistryRenal functionCreatinineSarcosine oxidaseCreatineCreatininaseHemodialysisChemistryBiosensorChromatography

摘要: Abstract Background : Creatinine is an important clinical laboratory parameter for the evaluation of kidney function. It essential to determine its concentration in serum patients suffering from renal insufficiency. During hemodialysis treatment, measurement creatinine effluent dialysate or ultrafiltrate may give additional information on efficiency extracorporal procedure. Therefore, enzyme sensors with co-immobilized amidohydrolase, creatine amidinohydrolase and sarcosine oxidase have been used creatinine. Methods Enzymatically generated hydrogen peroxide has amperometrically detected at a platinum-working electrode. To exclude electroactive compounds sample matrix, which might interfere electrochemical measurement, additionally modified by Nafion membrane. Results Such showed linear detection range 0.06–1.7 mg/dl Diluting measuring buffer, it also possible measure pathological concentrations up 11 mg/dl. A good correlation between serum, determined presented those obtained both, conventional colorimetric Jaffe enzymatic measurements achieved. Conclusion Further developments will aim integration this principle into concept low-cost disposable planar sensors.

参考文章(18)
Price Cp, Hoffmann Ge, Poppe Wa, Guder Wg, Siedel J, Hubbuch A, Multicentre evaluation of an enzymatic method for creatinine determination using a sensitive colour reagent. Clinical Chemistry and Laboratory Medicine. ,vol. 24, pp. 889- 902 ,(1986)
P Fossati, L Prencipe, G Berti, Enzymic creatinine assay: a new colorimetric method based on hydrogen peroxide measurement. Clinical Chemistry. ,vol. 29, pp. 1494- 1496 ,(1983) , 10.1093/CLINCHEM/29.8.1494
Eun Ju Kim, Tetsuya Haruyama, Yasuko Yanagida, Eiry Kobatake, Masuo Aizawa, Disposable creatinine sensor based on thick-film hydrogen peroxide electrode system Analytica Chimica Acta. ,vol. 394, pp. 225- 231 ,(1999) , 10.1016/S0003-2670(99)00308-6
Ansgar Erlenkötter, Mike Kottbus, Gabriele-Christine Chemnitius, Flexible amperometric transducers for biosensors based on a screen printed three electrode system Journal of Electroanalytical Chemistry. ,vol. 481, pp. 82- 94 ,(2000) , 10.1016/S0022-0728(99)00491-X
M. Meyerhoff, G.A. Rechnitz, An activated enzyme electrode for creatinine Analytica Chimica Acta. ,vol. 85, pp. 277- 285 ,(1976) , 10.1016/S0003-2670(01)84692-4
Klaus-Dieter Vorlop, Andreas Muscat, Jörg Beyersdorf, Entrapment of microbial cells within polyurethane hydrogel beads with the advantage of low toxicity Biotechnology Techniques. ,vol. 6, pp. 483- 488 ,(1992) , 10.1007/BF02447818
Andreas Muscat, Jörg Beyersdorf, Klaus-Dieter Vorlop, Poly(carbamoylsulphonate) hydrogel, a new polymer material for cell entrapment Biosensors and Bioelectronics. ,vol. 10, ,(1995) , 10.1016/0956-5663(95)96966-3
Bernd Gründig, Gunther Wittstock, Ulrich Rüdel, Beate Strehlitz, Mediator-modified electrodes for electrocatalytic oxidation of NADH Journal of Electroanalytical Chemistry. ,vol. 395, pp. 143- 157 ,(1995) , 10.1016/0022-0728(95)04090-B
N.G. Patel, A. Erlenkötter, K. Cammann, G.-C. Chemnitius, Fabrication and characterization of disposable type lactate oxidase sensors for dairy products and clinical analysis Sensors and Actuators B-chemical. ,vol. 67, pp. 134- 141 ,(2000) , 10.1016/S0925-4005(00)00410-X