Analytical aspects of hemodialysis

作者: Robert Koncki

DOI: 10.1016/J.TRAC.2008.01.014

关键词:

摘要: Abstract Clinical and biomedical analysis is one of the most significant fields modern analytical chemistry. Uremia a public-health problem. Chronic hemodialysis, common renal replacement therapy, life saving for more than million uremic patients world-wide this number increasing every year. This therapy consumes parts national budgets health as its costs are comparable with those intensive care. Hemodialysis treatment should, just like any other be individually prescribed, adequately administrated assessed. article reports on needs connected assessment therapy. I discuss main aspects including target analytes, choice samples, bioanalytical systems dedicated to control well methods required quantitation hemodialysis using data.

参考文章(43)
I. Fridolin, M. Magnusson, L.-G. Lindberg, On-line monitoring of solutes in dialysate using absorption of ultraviolet radiation: technique description. International Journal of Artificial Organs. ,vol. 25, pp. 748- 761 ,(2002) , 10.1177/039139880202500802
Christopher V Eddy, Mark A Arnold, Near-Infrared Spectroscopy for Measuring Urea in Hemodialysis Fluids Clinical Chemistry. ,vol. 47, pp. 1279- 1286 ,(2001) , 10.1093/CLINCHEM/47.7.1279
L Della Ciana, G Caputo, Robust, reliable biosensor for continuous monitoring of urea during dialysis. Clinical Chemistry. ,vol. 42, pp. 1079- 1085 ,(1996) , 10.1093/CLINCHEM/42.7.1079
Prem C. Pandey, A.P. Mishra, Novel potentiometric sensing of creatinine Sensors and Actuators B-chemical. ,vol. 99, pp. 230- 235 ,(2004) , 10.1016/J.SNB.2003.11.016
S ZAMPONI, B LOCICERO, M MASCINI, L DELLACIANA, S SACCO, Urea solid-state biosensor suitable for continuous dialysis control. Talanta. ,vol. 43, pp. 1373- 1377 ,(1996) , 10.1016/0039-9140(96)01880-2
Ewa Poboży, Anna Radomska, Robert Koncki, Stanisław Gła̧b, Determination of dialysate creatinine by micellar electrokinetic chromatography. Journal of Chromatography B. ,vol. 789, pp. 417- 424 ,(2003) , 10.1016/S1570-0232(03)00075-8
Bhusana Premanode, Chris Toumazou, A novel, low power biosensor for real time monitoring of creatinine and urea in peritoneal dialysis Sensors and Actuators B-chemical. ,vol. 120, pp. 732- 735 ,(2007) , 10.1016/J.SNB.2006.03.051
Bernd Tombach, Joachim Schneider, Fritz Matzkies, Roland M Schaefer, Gabriele C Chemnitius, Amperometric creatinine biosensor for hemodialysis patients. Clinica Chimica Acta. ,vol. 312, pp. 129- 134 ,(2001) , 10.1016/S0009-8981(01)00610-6
Robert Koncki, Anna Radomska, Stanisław Głąb, Potentiometric determination of dialysate urea nitrogen Talanta. ,vol. 52, pp. 13- 17 ,(2000) , 10.1016/S0039-9140(99)00346-X