A novel electrochemical DNA biosensor based on poly-(5-amino-2-mercapto-1,3,4-thiadiazole) modified glassy carbon electrode for the determination of nitrofurantoin

作者: Gözde Aydoğdu , Gülendem Günendi , Derya Koyuncu Zeybek , Bülent Zeybek , Şule Pekyardımcı

DOI: 10.1016/J.SNB.2014.02.083

关键词:

摘要: Abstract In this study, poly(5-amino-2-mercapto-1,3,4-thiadiazole) (PAMT) modified glassy carbon electrode (GCE) was fabricated and used for the electrochemical monitoring of interaction between dsDNA nitrofurantoin (NFT) first time. Electrochemical behavior PAMT GCE (GCE/PAMT) investigated by using cyclic voltammetry (CV) impedance spectroscopy (EIS) compared with those bare GCE. The GCE/PAMT/dsDNA prepared adsorption upon deposited binding NFT via differential pulse (DPV) method. decrease in guanine oxidation peak current at +0.82 V as an indicator 0.5 mol L−1 acetate buffer (pH 4.8) containing 0.02 mol L−1 NaCl. Under optimal conditions, currents were linearly proportional to concentrations range 2–25 mg L−1 detection limit found be 0.65 mg L−1. Furthermore, reproducibility, repeatability, stability applicability analysis pharmaceutical dosage forms human serum samples also examined. These results showed that DNA biosensor could sensitive, accurate precise determination NFT–dsDNA interaction.

参考文章(60)
Wei Wuji, Li Ying, Fu Haitao, Zhu Yifan, Study on the inhibiting behavior of AMT on bronze in 5% citric acid solution Journal of Materials Science. ,vol. 38, pp. 407- 411 ,(2003) , 10.1023/A:1021803211415
Mei-Rong Huang, Xin-Gui Li, Wei Duan, Effect of polymerization conditions on o-phenylenediamine and o-phenetidine oxidative copolymers Polymer International. ,vol. 54, pp. 70- 82 ,(2005) , 10.1002/PI.1618
Bushra Rafique, Ahmad M. Khalid, Kalsoom Akhtar, Abdul Jabbar, Interaction of anticancer drug methotrexate with DNA analyzed by electrochemical and spectroscopic methods. Biosensors and Bioelectronics. ,vol. 44, pp. 21- 26 ,(2013) , 10.1016/J.BIOS.2012.12.028
M.C Mahedero, T.Galeano Dı́az, S.Galán Pascual, Resolution of ternary mixtures of nitrofurantoin, furaltadone and furazolidone by partial least-square analysis to the spectrophotometric signals after photo-decomposition. Journal of Pharmaceutical and Biomedical Analysis. ,vol. 29, pp. 477- 485 ,(2002) , 10.1016/S0731-7085(02)00092-4
Bansi D. Malhotra, Asha Chaubey, S.P. Singh, Prospects of conducting polymers in biosensors. Analytica Chimica Acta. ,vol. 578, pp. 59- 74 ,(2006) , 10.1016/J.ACA.2006.04.055
Rajeev Jain, Ashish Dwivedi, Ritesh Mishra, Stripping voltammetric behaviour of toxic drug nitrofurantoin Journal of Hazardous Materials. ,vol. 169, pp. 667- 672 ,(2009) , 10.1016/J.JHAZMAT.2009.03.138
Juan-Carlos Vidal, Esperanza Garcia-Ruiz, Juan-Ram�n Castillo, Recent Advances in Electropolymerized Conducting Polymers in Amperometric Biosensors Mikrochimica Acta. ,vol. 143, pp. 93- 111 ,(2003) , 10.1007/S00604-003-0067-4