Intraocular Pressure in Children: The Effect of Body Position as Assessed by Icare and Tono-Pen Tonometers

作者: Eniolami O. Dosunmu , Inna Marcus , Irene Tung , Warakorn Thiamthat , Sharon F. Freedman

DOI: 10.1016/J.AJO.2014.09.009

关键词:

摘要: Purpose To explore the effect of body position (sitting vs supine) on intraocular pressure (IOP) in children, as assessed by Icare PRO and Tono-Pen. Design Prospective clinical study. Methods Children with known or suspected glaucoma those without were recruited from Duke Eye Center pediatric clinic. Subjects underwent tonometry both eyes while upright (sitting), after instillation topical anesthetic, either Tono-Pen first, then second instrument (order randomized). Goldmann applanation (GAT) was performed a clinician masked to previous measurements. The subjects placed supine for 5 minutes, using obtained, same order used when they sitting position. Results Enrolled 47 children (94 eyes). Mean seated IOP GAT, 16.4 ± 4.2, 17.5 3.5, 18.0 3.9 mm Hg, respectively. mean 18.4 4.5 18.8 4.2 mm This rise was +0.9 2.3 mm Hg ( P  = 0.01) and +0.7 1.8 mm 0.009), Conclusion In correlates well GAT position, positions. rises child changes measured However, increase, which is less than 1 mm seems clinically insignificant unlikely alter management children.

参考文章(15)
Nima Pakrou, Tim Gray, Richard Mills, John Landers, Jamie Craig, Clinical Comparison of the Icare Tonometer and Goldmann Applanation Tonometry Journal of Glaucoma. ,vol. 17, pp. 43- 47 ,(2008) , 10.1097/IJG.0B013E318133FB32
Kerstin Stephanie Jablonski, André Rosentreter, Stergiani Gaki, Alexandra Lappas, Thomas Stefan Dietlein, Clinical use of a new position-independent rebound tonometer. Journal of Glaucoma. ,vol. 22, pp. 763- 767 ,(2013) , 10.1097/IJG.0B013E318259AA47
Florin Grigorian, A. Paula Grigorian, Scott E. Olitsky, The use of the iCare tonometer reduced the need for anesthesia to measure intraocular pressure in children. Journal of Aapos. ,vol. 16, pp. 508- 510 ,(2012) , 10.1016/J.JAAPOS.2012.07.004
Ya-Chuan Hsiao, Jacqueline R. Dzau, Meghan S. Flemmons, Sanjay Asrani, Sarah Jones, Sharon F. Freedman, Home assessment of diurnal intraocular pressure in healthy children using the Icare rebound tonometer Journal of American Association for Pediatric Ophthalmology and Strabismus. ,vol. 16, pp. 58- 60 ,(2012) , 10.1016/J.JAAPOS.2011.10.005
Jong Yeon Lee, Chungkwon Yoo, Yong Yeon Kim, The effect of lateral decubitus position on intraocular pressure in patients with untreated open-angle glaucoma. American Journal of Ophthalmology. ,vol. 155, pp. 329- ,(2013) , 10.1016/J.AJO.2012.08.003
Nandini G. Gandhi, Sasapin G. Prakalapakorn, Mays A. El-Dairi, Sarah K. Jones, Sharon F. Freedman, Icare ONE Rebound Versus Goldmann Applanation Tonometry in Children With Known or Suspected Glaucoma American Journal of Ophthalmology. ,vol. 154, pp. 843- 849 ,(2012) , 10.1016/J.AJO.2012.05.003
P. Fernandes, J. A. Diaz-Rey, A. Queiros, J. M. Gonzalez-Meijome, J. Jorge, Comparison of the ICare® rebound tonometer with the Goldmann tonometer in a normal population Ophthalmic and Physiological Optics. ,vol. 25, pp. 436- 440 ,(2005) , 10.1111/J.1475-1313.2005.00327.X
Meghan S. Flemmons, Ya-Chuan Hsiao, Jacqueline Dzau, Sanjay Asrani, Sarah Jones, Sharon F. Freedman, Icare rebound tonometry in children with known and suspected glaucoma Journal of American Association for Pediatric Ophthalmology and Strabismus. ,vol. 15, pp. 153- 157 ,(2011) , 10.1016/J.JAAPOS.2010.11.022
Afsun Sahin, Hikmet Basmak, Leyla Niyaz, Nilgun Yildirim, None, Reproducibility and tolerability of the ICare rebound tonometer in school children. Journal of Glaucoma. ,vol. 16, pp. 185- 188 ,(2007) , 10.1097/IJG.0B013E31802FC6BC
Meghan S. Flemmons, Ya-Chuan Hsiao, Jacqueline Dzau, Sanjay Asrani, Sarah Jones, Sharon F. Freedman, Home Tonometry for Management of Pediatric Glaucoma American Journal of Ophthalmology. ,vol. 152, pp. 470- 478 ,(2011) , 10.1016/J.AJO.2011.03.001