Computational Fluid Dynamics within Bifurcated Abdominal Aortic Stent-Grafts:

作者: Benjamin A. Howell , Tom Kim , Angela Cheer , Harry Dwyer , David Saloner

DOI: 10.1177/152660280701400204

关键词:

摘要: Purpose:To assess the hemodynamic forces on a bifurcated abdominal aortic stent-graft under realistic conditions of flow, blood pressure, and sac pressure.Methods:Computational fluid dynamics was used to study temporal spatial variations in surface pressure shear through cardiac cycle models stent-grafts derived from computed tomography 4 patients who had previously undergone endovascular repair aneurysm (AAA). The trunk, bifurcation, limbs graft were analyzed separately as parts unified whole. Analyses repeated varying reflecting different perigraft flow diameter change.Results:Pressure-related far larger than flow-related all 3 segments cases. largest acted at bifurcation stent-graft. High pressures, seen with endoleak or dilatation, associated reduced transmural low-pr...

参考文章(17)
Irwin V. Mohan, Peter L. Harris, Corine J. van Marrewijk, Robert J. Laheij, Thien V. How, Factors and forces influencing stent-graft migration after endovascular aortic aneurysm repair. Journal of Endovascular Therapy. ,vol. 9, pp. 748- 755 ,(2002) , 10.1177/152660280200900606
Jae-Sung Cho, Ellen D Dillavou, Robert Y Rhee, Michel S Makaroun, Late abdominal aortic aneurysm enlargement after endovascular repair with the Excluder device. Journal of Vascular Surgery. ,vol. 39, pp. 1236- 1241 ,(2004) , 10.1016/J.JVS.2004.02.038
S.M Volodos, R.D Sayers, J.P Gostelow, Peter Bell, Factors Affecting the Displacement Force Exerted on a Stent Graft after AAA Repair—An In vitro Study European Journal of Vascular and Endovascular Surgery. ,vol. 26, pp. 596- 601 ,(2003) , 10.1016/J.EJVS.2003.08.002
Nuno V Dias, Krassi Ivancev, Martin Malina, Timothy Resch, Bengt Lindblad, Björn Sonesson, Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks. Journal of Vascular Surgery. ,vol. 39, pp. 1229- 1235 ,(2004) , 10.1016/J.JVS.2004.02.041
B.A. Howell, D. Saloner, J.M. LaBerge, T.A.M. Chuter, Pulsatile movement of the zenith aortic stent-graft Journal of Biomechanics. ,vol. 39, ,(2006) , 10.1016/S0021-9290(06)84058-3
W.Charles Sternbergh, Samuel R Money, Roy K Greenberg, Timothy A.M Chuter, Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the zenith multicenter trial Journal of Vascular Surgery. ,vol. 39, pp. 20- 26 ,(2004) , 10.1016/J.JVS.2003.09.022
P.W Walsh, S Chin-Quee, J.E Moore, Flow changes in the aorta associated with the deployment of a AAA stent graft Medical Engineering & Physics. ,vol. 25, pp. 299- 307 ,(2003) , 10.1016/S1350-4533(02)00216-3
N. Shahcheraghi, H. A. Dwyer, A. Y. Cheer, A. I. Barakat, T. Rutaganira, Unsteady and Three-Dimensional Simulation of Blood Flow in the Human Aortic Arch Journal of Biomechanical Engineering-transactions of The Asme. ,vol. 124, pp. 378- 387 ,(2002) , 10.1115/1.1487357
T Kim, A.Y Cheer, H.A Dwyer, A simulated dye method for flow visualization with a computational model for blood flow. Journal of Biomechanics. ,vol. 37, pp. 1125- 1136 ,(2004) , 10.1016/J.JBIOMECH.2003.12.028
Peter L. Harris, Jacob Buth, An update on the important findings from the EUROSTAR EVAR registry. Vascular. ,vol. 12, pp. 33- 38 ,(2003) , 10.1258/RSMVASC.12.1.33