Treatment of a patient with impaired renal function with gentamicin-PMMA-beads.

作者: G. H. I. M. Walenkamp , T. B. Vree

DOI: 10.1007/BF00389749

关键词:

摘要: 150 Gentamicin-PMMA-beads were implanted (+ 160 mg gentamicin i.v. preop.) in a woman aged 73 years and with severely impaired kidney function. Frequent determination of plasma concentrations renal functions possible. The concentration reached plateau at approx. 3 μg/ml. No accumulation occurred.

参考文章(2)
H Wahlig, E Dingeldein, R Bergmann, K Reuss, The release of gentamicin from polymethylmethacrylate beads. An experimental and pharmacokinetic study Journal of Bone and Joint Surgery-british Volume. pp. 270- 275 ,(1978) , 10.1302/0301-620X.60B2.659478
T. B. Vree, Y. A. Hekster, J. C. M. Hafkenscheid, R. van Dalen, W. T. Friesen, Myrella Roy, The Influence of Urine Flow on Renal Clearance of Creatinine in Patients with Normal and Impaired Kidney Function Annals of Pharmacotherapy. ,vol. 15, pp. 194- 198 ,(1981) , 10.1177/106002808101500305