作者: G. H. I. M. Walenkamp , T. B. Vree
DOI: 10.1007/BF00389749
关键词:
摘要: 150 Gentamicin-PMMA-beads were implanted (+ 160 mg gentamicin i.v. preop.) in a woman aged 73 years and with severely impaired kidney function. Frequent determination of plasma concentrations renal functions possible. The concentration reached plateau at approx. 3 μg/ml. No accumulation occurred.