Using Single-Channel Blind Deconvolution to Choose the Most Realistic Pharmacokinetic Model in Dynamic Contrast-Enhanced MR Imaging

作者: Torfinn Taxt , Tina Pavlin , Rolf K. Reed , Fitz-Roy Curry , Erling Andersen

DOI: 10.1007/S00723-015-0679-Y

关键词:

摘要: In dynamic contrast-enhanced magnetic resonance imaging, there has been no consensus in the choice of pharmacokinetic model. this paper, a new approach for assessment most realistic model given tissue is presented. Non-blind and single-channel blind deconvolution algorithms were used quantitative imaging mouse masseter muscle to compare realism two different models residue function. The first was adiabatic approximation homogeneity (aaJW) second, two-compartment exchange (2CXM). Normals mice treated with substance C48/80 studied. increases both blood flow contrast leakage substantially. obtained accuracy evaluated models. addition, arterial input functions (aifs) estimated using compared corresponding observed aifs. hypothesis that function leads best fits. non-blind did not result any clear answer. For deconvolution, aifs aaJW very similar aifs, clearly more so than 2CXM Also, tracer time sequences accurate describing passage through microvascular bed single could be assessed deconvolution.

参考文章(51)
Karen Egiazarian, Patrizio Campisi, Blind image deconvolution: theory and applications CRC Press. ,(2007) , 10.1201/9781420007299
Cheng Yang, Gregory S. Karczmar, Milica Medved, Walter M. Stadler, Multiple reference tissue method for contrast agent arterial input function estimation. Magnetic Resonance in Medicine. ,vol. 58, pp. 1266- 1275 ,(2007) , 10.1002/MRM.21311
M.M. Pike, C.N. Stoops, C.P. Langford, N.S. Akella, L.B. Nabors, G.Y. Gillespie, High-resolution longitudinal assessment of flow and permeability in mouse glioma vasculature: Sequential small molecule and SPIO dynamic contrast agent MRI† Magnetic Resonance in Medicine. ,vol. 61, pp. 615- 625 ,(2009) , 10.1002/MRM.21931
Steven Sourbron, Michael Ingrisch, Axel Siefert, Maximilian Reiser, Karin Herrmann, Quantification of cerebral blood flow, cerebral blood volume, and blood–brain-barrier leakage with DCE-MRI Magnetic Resonance in Medicine. ,vol. 62, pp. 205- 217 ,(2009) , 10.1002/MRM.22005
Dustin K. Ragan, Stephen Y. Lai, James A. Bankson, Fast, reproducible measurement of the vascular input function in mice using constrained reconstruction and cardiac sampling. NMR in Biomedicine. ,vol. 24, pp. 373- 384 ,(2010) , 10.1002/NBM.1601
R. Materne, A.M. Smith, F. Peeters, J.P. Dehoux, A. Keyeux, Y. Horsmans, B.E. Van Beers, Assessment of hepatic perfusion parameters with dynamic MRI. Magnetic Resonance in Medicine. ,vol. 47, pp. 135- 142 ,(2002) , 10.1002/MRM.10045
L. Hermoye, L. Annet, Ph. Lemmerling, F. Peeters, F. Jamar, P. Gianello, S. Van Huffel, B.E. Van Beers, Calculation of the renal perfusion and glomerular filtration rate from the renal impulse response obtained with MRI Magnetic Resonance in Medicine. ,vol. 51, pp. 1017- 1025 ,(2004) , 10.1002/MRM.20026
Melanie Heilmann, Christine Walczak, Julien Vautier, Jean-Luc Dimicoli, Carole D. Thomas, Mihaela Lupu, Joël Mispelter, Andreas Volk, Simultaneous dynamic T1 and T2* measurement for AIF assessment combined with DCE MRI in a mouse tumor model. Magnetic Resonance Materials in Physics Biology and Medicine. ,vol. 20, pp. 193- 203 ,(2007) , 10.1007/S10334-007-0082-2
Gunnar Brix, Fabian Kiessling, Robert Lucht, Susanne Darai, Klaus Wasser, Stefan Delorme, J�rgen Griebel, Microcirculation and microvasculature in breast tumors: Pharmacokinetic analysis of dynamic MR image series Magnetic Resonance in Medicine. ,vol. 52, pp. 420- 429 ,(2004) , 10.1002/MRM.20161
Damir B. Matic, Ting Y. Lee, R Glenn Wells, Bing S. Gan, The effects of botulinum toxin type A on muscle blood perfusion and metabolism. Plastic and Reconstructive Surgery. ,vol. 120, pp. 1823- 1833 ,(2007) , 10.1097/01.PRS.0000287135.17291.2F