Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements.

作者: E L Madsen , F Dong , G R Frank , B S Garra , K A Wear

DOI: 10.7863/JUM.1999.18.9.615

关键词:

摘要: In a study involving 10 different sites, independent results of measurements ultrasonic properties on equivalent tissue-mimicking samples are reported and compared. The measured were propagation speed, attenuation coefficients, backscatter coefficients. Reasonably good agreement exists for but less satisfactory found speeds. As anticipated, was not impressive in the case Results four sites agreed rather well both absolute values frequency dependence, from other lower by as much an order magnitude. is valuable laboratories doing quantitative studies.

参考文章(24)
Keith A. Wear, Brian S. Garra, Timothy J. Hall, Measurements of ultrasonic backscatter coefficients in human liver and kidney in vivo. Journal of the Acoustical Society of America. ,vol. 98, pp. 1852- 1857 ,(1995) , 10.1121/1.413372
A.R. Selfridge, Approximate Material Properties in Isotropic Materials IEEE Transactions on Sonics and Ultrasonics. ,vol. 32, pp. 381- 394 ,(1985) , 10.1109/T-SU.1985.31608
Frederick W. Kremkau, Ralph W. Barnes, C. Patrick McGraw, Ultrasonic attenuation and propagation speed in normal human brain Journal of the Acoustical Society of America. ,vol. 70, pp. 29- 38 ,(1981) , 10.1121/1.386578
M M Burlew, E L Madsen, J A Zagzebski, R A Banjavic, S W Sum, A new ultrasound tissue-equivalent material. Radiology. ,vol. 134, pp. 517- 520 ,(1980) , 10.1148/RADIOLOGY.134.2.7352242
Lin Xin Yao, James A. Zagzebski, Ernest L. Madsen, Backscatter Coefficient Measurements Using a Reference Phantom to Extract Depth-Dependent Instrumentation Factors Ultrasonic Imaging. ,vol. 12, pp. 58- 70 ,(1990) , 10.1177/016173469001200105
Ernest L. Madsen, James A. Zagzebski, Micheal C. Macdonald, Gary R. Frank, Ultrasound focal lesion detectability phantoms Medical Physics. ,vol. 18, pp. 1171- 1180 ,(1991) , 10.1118/1.596589
Michael F. Insana, Timothy J. Hall, Parametric Ultrasound Imaging from Backscatter Coefficient Measurements: Image Formation and Interpretation Ultrasonic Imaging. ,vol. 12, pp. 245- 267 ,(1990) , 10.1177/016173469001200402
JA Zagzebski, ZF Lu, LX Yao, None, Quantitative Ultrasound Imaging: In Vivo Results in Normal Liver Ultrasonic Imaging. ,vol. 15, pp. 335- 351 ,(1993) , 10.1177/016173469301500405
James J. Faran, Sound Scattering by Solid Cylinders and Spheres Journal of the Acoustical Society of America. ,vol. 23, pp. 405- 418 ,(1951) , 10.1121/1.1906780
K. K. Shung, Y. W. Yuan, D. Y. Fei, J. M. Tarbell, Effect of flow disturbance on ultrasonic backscatter from blood. Journal of the Acoustical Society of America. ,vol. 75, pp. 1265- 1272 ,(1984) , 10.1121/1.390733