ASSESSMENT OF IN VITRO DENTAL IMPLANT PRIMARY STABILITY USING AN ULTRASONIC METHOD

作者: Romain Vayron , Vincent Mathieu , Adrien Michel , Guillaume Haïat

DOI: 10.1016/J.ULTRASMEDBIO.2014.03.035

关键词:

摘要: Abstract Dental implants are used for oral rehabilitation. However, there remain risks of failure that depend on the implant stability. The objective this study is to investigate whether quantitative ultrasound technique can be assess amount bone in contact with dental implants. Ten first inserted samples. 10 MHz ultrasonic response each measured using a dedicated device and an indicator I derived based amplitude signal. Then, unscrewed by 2 π radians measurement realized again. A statistical analysis variance was carried out revealed significant effect values (p value

参考文章(41)
L Sennerby, N Meredith, B Friberg, C Aparicio, Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. International Journal of Prosthodontics. ,vol. 11, pp. 269- 275 ,(1998)
Nicolas Meeùs, Malou M-Louise Haine, De Smet L. P. Mardaga. pp. 132- 133 ,(1986)
SILKE HECHT, WILLIAM H. ADAMS, JILL NARAK, WILLIAM B. THOMAS, Magnetic Resonance Imaging Susceptibility Artifacts Due to Metallic Foreign Bodies Veterinary Radiology & Ultrasound. ,vol. 52, pp. 409- 414 ,(2011) , 10.1111/J.1740-8261.2011.01809.X
Tomas Albrektsson, Evert Dahl, Lars Enbom, Sigfrid Engevall, Bo Engquist, Anders R. Eriksson, Günther Feldmann, Nils Freiberg, Per-Olof Glantz, Olof Kjellman, Lars Kristersson, Sven Kvint, Per-Åke Köndell, Jan Palmquist, Lars Werndahl, Per Åstrand, Osseointegrated Oral Implants Journal of Periodontology. ,vol. 59, pp. 287- 296 ,(1988) , 10.1902/JOP.1988.59.5.287
Pilar Valderrama, Thomas W. Oates, Archie A. Jones, James Simpson, John D. Schoolfield, David L. Cochran, Evaluation of two different resonance frequency devices to detect implant stability: A clinical trial Journal of Periodontology. ,vol. 78, pp. 262- 272 ,(2007) , 10.1902/JOP.2007.060143
Romain Vayron, Patrick Karasinski, Vincent Mathieu, Adrien Michel, Domitille Loriot, Gilles Richard, Gregory Lambert, Guillaume Haiat, Variation of the ultrasonic response of a dental implant embedded in tricalcium silicate-based cement under cyclic loading. Journal of Biomechanics. ,vol. 46, pp. 1162- 1168 ,(2013) , 10.1016/J.JBIOMECH.2013.01.003
Mark W. Richards, Jeffery J. Becker, Natalie E. Monaco, Ali Kanawati, Measurement of Clinicians' Ability to Hand Torque Dental Implant Components Journal of Oral Implantology. ,vol. 35, pp. 185- 188 ,(2009) , 10.1563/1548-1336-35.4.185
Shiro Biwa, Shunsuke Hiraiwa, Eiji Matsumoto, Stiffness evaluation of contacting surfaces by bulk and interface waves Ultrasonics. ,vol. 47, pp. 123- 129 ,(2007) , 10.1016/J.ULTRAS.2007.08.005
Patrick T. Knott, Steven M. Mardjetko, Richard H. Kim, Timothy M. Cotter, Megan M. Dunn, Shivani T. Patel, Matthew J. Spencer, Alan S. Wilson, David S. Tager, A comparison of magnetic and radiographic imaging artifact after using three types of metal rods: stainless steel, titanium, and vitallium The Spine Journal. ,vol. 10, pp. 789- 794 ,(2010) , 10.1016/J.SPINEE.2010.06.006
V. Pattijn, S.V.N. Jaecques, E. De Smet, L. Muraru, C. Van Lierde, G. Van der Perre, I. Naert, J. Vander Sloten, Resonance frequency analysis of implants in the guinea pig model: influence of boundary conditions and orientation of the transducer. Medical Engineering & Physics. ,vol. 29, pp. 182- 190 ,(2007) , 10.1016/J.MEDENGPHY.2006.02.010