Design and Development of a Breath Acetone MOS Sensor for Ketogenic Diets Control

作者: Giovanni Neri , Anna Bonavita , Giuseppe Micali , Nicola Donato

DOI: 10.1109/JSEN.2009.2035663

关键词:

摘要: The design of a handy and noninvasive measurement acetone in the human breath, which is useful for ketosis monitoring control, by means MOS sensors reported. For this aim, highly sensitive resistive thick film configuration, fabricated depositing sensing layers In2O 3 Pt-In2O nanopowders screen-printing, have been developed. devices were calibrated using standard gases laboratory, showing high sensitivity linear response range concentration investigated (1-100 ppm). results obtained indicate that based on are promising as fast quantifiable determining posing advantages real time measurements low costs control ketogenic diets.

参考文章(36)
S Vogrin, JA Lawson, I Stewart, MJ Cook, AF Bleasel, Ame Bye, Detection of widespread cerebral and cerebellar volume loss by quantitative MRI in childhood intractable epilepsy syndromes. Epilepsia. ,vol. 40, pp. 221- 221 ,(1999)
Wang Ping, Tan Yi, Xie Haibao, Shen Farong, A novel method for diabetes diagnosis based on electronic nose. Biosensors and Bioelectronics. ,vol. 12, pp. 1031- 1036 ,(1997) , 10.1016/S0956-5663(97)00059-6
Kathy Musa-Veloso, Sergei S Likhodii, Stephen C Cunnane, Breath acetone is a reliable indicator of ketosis in adults consuming ketogenic meals The American Journal of Clinical Nutrition. ,vol. 76, pp. 65- 70 ,(2002) , 10.1093/AJCN/76.1.65
Kristine L. Danowski, Paul E. Cranley, Larry Sun, Reed A. Schick, Bettina M. Rosner, James A. McIntyre, Jeffrey R. Allen, Hand-held medical apparatus ,(2002)
Noboru Yamazoe, Kengo Shimanoe, Roles of Shape and Size of Component Crystals in Semiconductor Gas Sensors I. Response to Oxygen Journal of The Electrochemical Society. ,vol. 155, ,(2008) , 10.1149/1.2832655
S K Kundu, J A Bruzek, R Nair, A M Judilla, Breath acetone analyzer: diagnostic tool to monitor dietary fat loss. Clinical Chemistry. ,vol. 39, pp. 87- 92 ,(1993) , 10.1093/CLINCHEM/39.1.87
B P J de Lacy Costello, R J Ewen, N M Ratcliffe, M Richards, The characteristics of novel low-cost sensors for volatile biomarker detection Journal of Breath Research. ,vol. 2, pp. 037017- ,(2008) , 10.1088/1752-7155/2/3/037017
Daniel LA Fernandes, Tony A Rolo, João ABP Oliveira, MTSR Gomes, None, A new analytical system, based on an acoustic wave sensor, for halitosis evaluation Sensors and Actuators B-chemical. ,vol. 136, pp. 73- 79 ,(2009) , 10.1016/J.SNB.2008.10.037
James C. Garriott, Eberhard Foerster, Louis Juarez, Fidel De la Garza, Ivan Mendiola, Jason Curoe, Measurement of Toluene in Blood and Breath in Cases of Solvent Abuse Clinical Toxicology. ,vol. 18, pp. 471- 479 ,(1981) , 10.3109/15563658108990271