Pulse Oximeter Changes With Sentinel Lymph Node Biopsy in Breast Cancer

作者: Mahmoud El-Tamer , Ian K Komenaka , Saundra Curry , Andrea B Troxel , Beth-Ann Ditkoff

DOI: 10.1001/ARCHSURG.138.11.1257

关键词:

摘要: Hypothesis The changes reported with pulse oximetry after the injection of isosulfan blue for sentinel lymph node identification in patients breast cancer are consistent and predictable. Design Retrospective study. Setting University hospital. Patients Methods complete anesthesia records 92 who underwent biopsy intraparenchymal were reviewed. study extended from January 1999 to February 2000. operations all performed patient received general anesthesia. We injected 5 mL into tissue surrounding tumor. data reviewed included preinjection oximeter saturation readings postinjection values continuing until returned baseline levels postanesthesia care unit. Main Outcome Measures Changes oxygen before blue. Results Isosulfan interfered measurements a substantial time—as much as 195 minutes. mean time maximum change reading was 35 median decrease 5%. 11%. Conclusions Although can be substantial, their course appears predictable, therefore most otherwise healthy normal pulmonary function, invasive monitoring is not necessary.

参考文章(15)
Frederick G. Mihm, Bruce D. Halperin, Noninvasive Detection of Profound Arterial Desaturations Using a Pulse Oximetry Device Anesthesiology. ,vol. 62, pp. 85- 87 ,(1985) , 10.1097/00000542-198501000-00020
Christian M. Alexander, Lynn E. Teller, Jeffrey B. Gross, Principles of pulse oximetry: theoretical and practical considerations. Anesthesia & Analgesia. ,vol. 68, pp. 368- 376 ,(1989) , 10.1213/00000539-198903000-00035
MICHAEL R. KESSLER, THOMAS EIDE, BHARATHI HUMAYUN, PAUL J. POPPERS, Spurious Pulse Oximeter Desaturation with Methylene Blue Injection Anesthesiology. ,vol. 65, pp. 435- 436 ,(1986) , 10.1097/00000542-198610000-00017
Gerald W. Peskin, The Best of the Best—2001 Archives of Surgery. ,vol. 137, pp. 862- 864 ,(2002) , 10.1001/ARCHSURG.137.7.862
I. Yoshiya, Y. Shimada, K. Tanaka, Spectrophotometric monitoring of arterial oxygen saturation in the fingertip Medical & Biological Engineering & Computing. ,vol. 18, pp. 27- 32 ,(1980) , 10.1007/BF02442476
Arnold DK Hill, Katherine N Tran, Tim Akhurst, Henry Yeung, Samuel DJ Yeh, Paul Peter Rosen, Patrick I Borgen, Hiram S Cody III, None, Lessons learned from 500 cases of lymphatic mapping for breast cancer. Annals of Surgery. ,vol. 229, pp. 528- 535 ,(1999) , 10.1097/00000658-199904000-00012
A.-M. Koivusalo, K. Von Smitten, L. Lindgren, Sentinel node mapping affects intraoperative pulse oximetric recordings during breast cancer surgery Acta Anaesthesiologica Scandinavica. ,vol. 46, pp. 411- 414 ,(2002) , 10.1034/J.1399-6576.2002.460414.X
Jorg Dotsch, Suha Demirakca, Dorle Hahn, Norbert Katz, Peter Gonne Kuhl, Wolfgang Rascher, Accuracy of methemoglobin measurements: comparison of six different commercial devices and one manual method. Critical Care Medicine. ,vol. 27, pp. 1191- 1194 ,(1999) , 10.1097/00003246-199906000-00051