An optical glucose biosensor based on glucose oxidase immobilized on a swim bladder membrane

作者: Zaide Zhou , Lina Qiao , Peng Zhang , Dan Xiao , Martin M. F. Choi

DOI: 10.1007/S00216-005-0023-8

关键词:

摘要: An optical glucose biosensor using a swim bladder membrane as an enzyme immobilization platform and oxygen-sensitive oxygen transducer has been developed. During the enzymatic reaction, is oxidized by oxidase with concomitant consumption of dissolved resulting in increase fluorescence intensity transducer. The directly related to concentration. effects pH, temperature, buffer concentration, selectivity have studied detail. immobilized retained 80% its initial activity after being kept for more than 10 months at 4°C. successfully applied determination content human blood serum urine samples.

参考文章(19)
A. Pinazo, EFFECT OF SURFACTANT STRUCTURE ON DIFFUSION THROUGH A COLLAGEN MEMBRANE Colloids and Surfaces B: Biointerfaces. ,vol. 8, pp. 63- 72 ,(1996) , 10.1016/S0927-7765(96)01306-9
Walter Murphy, An Example to Follow Analytical Chemistry. ,vol. 25, pp. 1- 1 ,(1953) , 10.1021/AC60073A600
Lei Su, Xinping Qiu, Lianghong Guo, Fushi Zhang, Chenhe Tung, Amperometric glucose sensor based on enzyme-modified boron-doped diamond electrode by cross-linking method Sensors and Actuators B-chemical. ,vol. 99, pp. 499- 504 ,(2004) , 10.1016/J.SNB.2003.12.069
L.I. Boguslavsky, L. Geng, I.P. Kovalev, S.K. Sahni, Z. Xu, T.A. Skotheim, V. Laurinavicius, B. Persson, L. Gorton, Amperometric thin film biosensors based on glucose dehydrogenase and Toluidine Blue O as catalyst for NADH electrooxidation. Biosensors and Bioelectronics. ,vol. 10, pp. 693- 704 ,(1995) , 10.1016/0956-5663(95)96960-7
Valérie C. Tsafack, Christophe A. Marquette, Béatrice Leca, Loïc J. Blum, An electrochemiluminescence-based fibre optic biosensor for choline flow injection analysis. Analyst. ,vol. 125, pp. 151- 155 ,(2000) , 10.1039/A907709J
Ingo. Klimant, Otto S. Wolfbeis, Oxygen-Sensitive Luminescent Materials Based on Silicone-Soluble Ruthenium Diimine Complexes Analytical Chemistry. ,vol. 67, pp. 3160- 3166 ,(1995) , 10.1021/AC00114A010
M. Portaccio, M. El-Masry, N. Rossi Diano, A. De Maio, V. Grano, M. Lepore, P. Travascio, U. Bencivenga, N. Pagliuca, D.G. Mita, An amperometric sensor employing glucose oxidase immobilized on nylon membranes with different pore diameter and grafted with different monomers Journal of Molecular Catalysis B-enzymatic. ,vol. 18, pp. 49- 67 ,(2002) , 10.1016/S1381-1177(02)00058-9